Smartdop® 30EX

$3,465.00 (inc GST) $3,150.00 (exc GST)
Shipping:
Calculated at checkout

Product Description

 

Bi-directional Doppler for ABI / TBI studies with built-in cuff inflator.

Displays & prints velocity / pressure waveform & numerical data.

30 waveform memory & USB interface.

Backlit LCD for easy visualization.

Built-in PV capability.

Vascular Link Software Smart-V-Link for Windows (Option).

Ni-MH rechargeable battery pack or AC adaptor.

2 probe connections available.

Simple fetal heart rate available used with 2 MHz probe.

PPG probe (Option)

 

sd30ex.jpg

 

Smartdop 30EX Quick Guide to ABI & TBI Pressures

Stage 1 – Brachial Pressure

1. Couple the standard cuff to the inflation inlet using the clear tubing.
2. Connect the 8MHZ probe into the probe connector #1 (on the right side of the machine) and select probe #1 on the face of the machine
3. Using the mode button, highlight the ARM/LEG mode
4. Apply the standard cuff around the arm and place the 8MHZ probe to obtain brachial blood flow.
5. Once a satisfactory reading is obtained the INF/DUMP light will flash. Acknowledge by pressing the INF/DUMP button to commence cuff inflation and deflation.
6. Once a systolic pressure is obtained press the ARM button to save.
Press the print button for 2 seconds to print the ABI report

Stage 2 – Ankle Pressure

1. Apply the standard cuff around the leg and place the 8MHZ probe to obtain a leg blood flow reading.
2. Once a satisfactory reading is obtained the INF/DUMP light will flash. Acknowledge by pressing the INF/DUMP button to commence cuff inflation and deflation.
3. Once a systolic pressure is obtained press the LEG/TOE button to save.
This will automatically give you the ABI reading.
Press the print button for 2 seconds to print the ABI Report.

Stage 3- Toe Pressure

1. Couple the digital cuff to the inflation inlet using the clear tubing.
2. Connect the PPG probe into the probe connector #2 (on the back of the machine) and select probe #2 on the face of the machine.
3. Using the mode button, highlight TOE mode.
4. Apply the digital cuff around the TOE and secure the PPG probe to the toe
5. Once satisfactory reading is obtained the INF/DUMP light will flash. Acknowledge by pressing the INF/DUMP button to commence cuff inflation and deflation.
6. Once a systolic pressure is obtained press the LEG/TOE button to save.
This will automatically give you a TBI reading.
Press the Print button for 2 seconds to print the TBI report.

 